scoutklion.blogg.se

Dynamic light scattering machine
Dynamic light scattering machine










  1. Dynamic light scattering machine full#
  2. Dynamic light scattering machine software#

  • Temperature is controlled and continuously measured in the instrumentįor advanced measurements, a few more parameters need to be selected or entered into DYNAMICS:.
  • dynamic light scattering machine dynamic light scattering machine

  • No sample-specific properties such as concentration or composition are required to assess size, size distributions and aggregation.
  • Dynamic light scattering machine software#

    Moreover, DYNAMICS ® software contains an extensive, built-in solvent library with the most common solvents and buffer systems, including the option to create custom solvents. Solvent viscosity and refractive index are generally well-known and tabulated.The only necessary input parameters are solution viscosity and refractive index.ĭLS is a technique that can be readily applied for sizing unknown samples: The resulting intensity fluctuations in the light scattering detector are analyzed to determine a translational diffusion coefficient, which is converted to hydrodynamic radius via the Stokes-Einstein relationship (see sidebar). The sample is illuminated with a laser beam, and light waves scattered from the particles interfere constructively and destructively as the particles diffuse randomly. Pre-screening: Ideal to check sample quality before running other expensive and time-consuming biophysical methods such as TEM, AUC, SAXS/SANS, FFF and SEC.įor in-depth characterization of high-resolution size distributions and other physical properties, SEC-MALS and FFF-MALS offer complementary and orthogonal techniques to DLS.ĭLS determines the hydrodynamic size of a nanoparticle in solution by measuring the time scale of Brownian motion.Advanced properties: Measure particle concentration, nonspecific interactions ( A 2 or B 22) and differentiate between conformational changes and aggregation with the static light scattering option in the NanoStar and Plate Reader.Versatility: Beyond size and size distributions, measure other properties such as stability, stress-induced aggregation and molecular interactions.No shearing or filtering: always measure what’s in your solution.Low sample volume: Only 2 µL in the DynaPro NanoStar using quartz cuvettes, 4 µL in disposable cuvettes or standard microwell plates in the DynaPro Plate Reader.Non-destructive and fully recoverable: Samples may be transferred to other assays.

    Dynamic light scattering machine full#

    Full nanometer size range: from 0.5 nm to 2.5 µm in a single measurement, with a resolution up to a factor of 3-5 in size.

    dynamic light scattering machine

  • Dynamic & Electrophoretic Light ScatteringĭLS is an ideal screening tool for biopharmaceutical formulations and other nanomaterials.











  • Dynamic light scattering machine